This fellow measured his compressor outlet.
Air compressor line cooler.
If the temperature at the discharge port exceeds 300 degrees fahrenheit the refrigerant oil and adjacent mechanisms.
Make no mistake a cooler alone does not yield high quality compressed air.
Air cooled aftercoolers use ambient air to cool the hot compressed air.
The compressed air travels through either the spiral finned tube coil or a plate fin coil design of the aftercooler while ambient air is forced over the cooler by a motor driven fan.
5 hp quiet air compressor 1ph 2 stage 80 gallon vertical emax yellow industrial series model es05v080i1 by emax compressor 5 0 out of 5 stars 5 2 499 00 2 499.
Removing the liquid requires a moisture separator and a drain valve.
In a reciprocating air compressor for example the air temperature will drop anywhere from 50 degrees fahrenheit to 75 degrees fahrenheit across the roughly six inches of travel between the discharge port and discharge line.
In small air systems 20 hp it s common to see the receiver tank used to separate and collect liquids.
Aftercoolers are heat exchangers for cooling the discharge from a air compressor.
They use either air or water and are an effective means of removing moisture from compressed air.
Aftercoolers reduce the amount of water vapor in a compressed air system by condensing the water vapor into liquid form.
Cooling condenses lots of water.
The compressed air enters the air cooled aftercooler.